TriggeredTiltBase.SensorEdit Method

Allows for the update of the specific type of sensor.

Syntax
C#
public static void SensorEdit(ISensor sens, double? heartBeat, double? minimumPitchThreshold, double? maximumPitchThreshold, int? measurementStability, int? stuckTimeOut, int? axisMode, int? dataMode, int? awareMode, int? rearmTime, double? deltaValue, int? failedTransmissionsBeforeLinkMode);
Parameters 
Description 
ISensor sens 
sens the Sensor object to be updated  
double? heartBeat 
How often the sensor communicates with the gateway if no activity recorded. 
double? minimumPitchThreshold 
Any Pitch below this threshold will put the sensor in the Aware State. 
double? maximumPitchThreshold 
Any Pitch above this threshold will put the sensor in the Aware State. 
int? measurementStability 
Number of measurements after a movement into a valid UP or DOWN region to wait until reporting the current pitch and status 
int? stuckTimeOut 
Number of seconds after movement out of a valid UP or DOWN region to wait until reporting stuck 
int? axisMode 
Rotational Axis that the sensor will tilt around. (0 is +X, 1 is -X, 2 is +Y, 3 is -Y, 4 is +Z, 5 is -Z) (ONLY ENABLED FOR ALTA MODE) 
int? dataMode 
Select 1= Up/Down vs 0 = Delta MODE 
int? awareMode 
0= None/ 1 = On Change(Delta Exceeded)/2 = Not Down/ 3 = Not Up / 4= Stuck [Delta Mode only shows options 0 and 1] 
int? rearmTime 
After the sensor triggers due to the delta value being exceeded, it must wait this long before it can trigger again 
int? failedTransmissionsBeforeLinkMode 
The number of transmissions the sensor sends without response from a gateway before it goes to battery saving link mode. In link mode the sensor will scan for a new gateway and if not found will enter battery saving sleep mode for 2 hours before trying to scan again. Lower number will allow sensors to find new gateways with fewer missed readings. Higher numbers will cause the sensor to hold it setting in a noisy RF environment better. (Zero will cause the sensor to never enter link mode. to find a new gateway channel the battery will have to be cycled out of the sensor.) 