HandheldFoodProbeBase.SensorEdit Method

Allows for the update of the specific type of sensor.

Syntax
C#
public static void SensorEdit(ISensor sens, double? heartBeat, double? minimumThreshold, double? maximumThreshold, int? displayTimeOut, double? sessionTimeThreshold, double? sessionReportInterval, int? Offset, int? failedTransmissionsBeforeLinkMode);
Parameters 
Description 
ISensor sens 
sens the Sensor object to be updated  
double? heartBeat 
How often the sensor communicates with the gateway if no activity recorded. 
double? minimumThreshold 
Any assessments below this Celsius value will cause the sensor to enter the Aware State. 
double? maximumThreshold 
Any assessments above this Celsius value will cause the sensor to enter the Aware State. 
int? displayTimeOut 
Length of time LCD display will stay on after turning on. 
double? sessionTimeThreshold 
When in a record "session", this value determines how long the session will continue before timing out and returning to normal sensor operations 
double? sessionReportInterval 
When in a record "session", this value determines how often the sensor will report in 
int? Offset 
Offsets the Celsius value reported by the sensor, with an adjustment range of -50.0 to 50.0 
int? failedTransmissionsBeforeLinkMode 
The number of transmissions the sensor sends without response from a gateway before it goes to battery saving link mode. In link mode the sensor will scan for a new gateway and if not found will enter battery saving sleep mode for 2 hours before trying to scan again. Lower number will allow sensors to find new gateways with fewer missed readings. Higher numbers will cause the sensor to hold it setting in a noisy RF environment better. (Zero will cause the sensor to never enter link mode. to find a new gateway channel the battery will have to be cycled out of the sensor.) 