Sensor Members

The following tables list the members exposed by Sensor.

 
Name 
Description 
 

description of the sensor type if it is triggered or interval based  
 

The firmware of the sensor  
 

set when the ReportInterval, ActiveStateInterval or TransmitIntervalLink  
 

set when Recovery is changed  
 

the type of sensor being used such as temperature or humidity  
 

Once the recovery count is reached, the sensor will go to link mode and begin scanning channels and trying to find a gateway to join  
 

how often the sensor will send non aware data to a gateway  
 

How many times recovery should happen  
 

the unique sensor identifier  
 

How often the sensor attempts to re-link with a gateway once it goes into link mode. Values below 12 are interpreted as hours. values above 12 are interpreted as minutes. the max value allowed in this field is 250. if a value of 0 is given the sensor will default to a re-link interval of 2 hours  
Public Constructors
 
Name 
Description 
 
This is the overview for the Sensor constructor overload. 
Public Methods
 
Name 
Description 
 

this is now handled by the sensors base application class
 
 
This is the overview for the BatteryPercentageHelper method overload. 
 

 
 

gets if acc has been set for the sensor  
 

this is now handled by the sensors base application class
 
 

gets the aware state heartbeat for the sensor  
 

gets what the bistable value has been set as  
 

gets calibration 1 value  
 

gets calibration 2 value  
 

gets calibration 3 value  
 

gets calibration 4 value  
 

 
 

gets the event detection count  
 

gets event detection period  
 

gets the type of event that will put the trigger sensor in aware  
 

gets the firmware version for the sensor  
 

gets if update should take place  
 

gets if general config 2 values should be updated or not.  
 

gets the hysteresis value  
 

gets the maximum aware threshold  
 

gets how many times during a report interval the sensor will take a measurement  
 

gets the minimum aware threshold  
 

gets the application profile type of the sensor  
 

gets if pending action control command has been set  
 

gets if there needs to be an update  
 

lets you know if calibration 1 through 4 has been changed  
 

get how long in seconds it take to allow a trigger type sensor to be able to be re-triggered  
 

gets the value that should be reached before link mode  
 

gets the normal heartbeat for the sensor  
 

gets how many times the sensor will attempt to reconnect to the gateway  
 

gets the sensors unique identifier  
 

gets How often the sensor attempts to re-link with a gateway once it goes into link mode. Values below 12 are interpreted as hours. values above 12 are interpreted as minutes. the max value allowed in this field is 250. if a value of 0 is given the sensor will default to a re-link interval of 2 hours  
 

marks all flags for update false  
 

this is now handled by the sensors base application class
 
 

this is now handled by the sensors base application class
 
 

sets the action control command
 
 

this is now handled by the sensors base application class
 
 

sets the aware state heartbeat for the sensor
 
 

If Aware Reading is selected, then the time between the message detecting motion and the message saying 'no motion' is (rearm time + aware state heartbeat). If set to All State Changes, then the time between the two messages is (rearm time + rearm time).This example assumes standard Aware on Motion state.
 
 

sets calibration 1
 
 

sets calibration 2
 
 

sets calibration 3
 
 

sets calibration 4
 
 

 
 

determine by sensor type
 
 

determined by sensor type
 
 

sets which reading of the sensor will trigger the aware state for trigger sensors
 
 

sets if general config 1 values should be updated
 
 

sets if GeneralConfig2Dirty values should be updated
 
 

A buffer to prevent the sensor from bouncing between standard operation and aware state when the assessments are very close to a threshold. for example, if a maximum threshold is set to 90 degrees and a hysteresis of 1 degree, then once the sensor takes an assessment of 90.0 degrees and enters the aware state it will remain in the aware state until the temperature readings drop to 89.0 degrees
 
 

sets the maximum threshold of the aware state
 
 

sets how many times during the heartbeat a measurement should be taken an example would be if you have a 10 minute reportinterval and you set this value to 2 every 5 minutes a measurement will be taken and if it is in the aware state it will send the data out otherwise it will wait until the report interval to be met to send the data to the gateway.
 
 

sets the minimum threshold of the aware state
 
 

allows you to set pending action control command
 
 

allows you to set this value to true if specific values you need to updated  
 

set to true if any calibration 1 through 4 has been changed
 
 

set how long in seconds it take to allow a trigger type sensor to be able to be re-triggered  
 

Once the recovery count is reached, the sensor will go to link mode and begin scanning channels and trying to find a gateway to join
 
 

sets the retry count on the sensor
 
 

this is now handled by the sensors base application class
 
 

this is now handled by the sensors base application class
 
 

this is now handled by the sensors base application class
 
 

this is now handled by the sensors base application class
 