Sensor sens |
the Sensor object to be updated |
Double heartBeat |
How often the sensor communicates with the gateway if no activity recorded. |
Integer maximumThreashold |
Any assessments above this value will cause the sensor to enter the Aware State. |
Boolean accumulate |
Standard operation reports the number of pulses detected between heartbeats. Accumulate on will accumulate the readings heartbeat after heartbeat. accumulation rolls over at 65535. |
Integer pulseEdgeDetection |
determines whether pulses are recorded at the positive edge of the pulse or the negative edge of the pulse. Positive edge = 0, Negative Edge = 1, or both edges = 2 |
Integer stabilizationDelay |
Milliseconds to wait for confirming positive reading after pulse initially detected.(Debouncing) Recommended 50% of minimum pulse width of input signal. |
Integer failedTransmissionsBeforeLinkMode |
The number of transmissions the sensor sends without response from a gateway before it goes to battery saving link mode. In link mode the sensor will scan for a new gateway and if not found will enter battery saving sleep mode for 2 hours before trying to scan again. Lower number will allow sensors to find new gateways with fewer missed readings. Higher numbers will cause the sensor to hold it setting in a noisy RF environment better. (Zero will cause the sensor to never enter link mode. to find a new gateway channel the battery will have to be cycled out of the sensor.) |