Java Mine
ContentsIndexHome
PreviousUpNext
CurrentZeroToTwentyAmpBase Members

The following tables list the members exposed by CurrentZeroToTwentyAmpBase.

 
Name 
Description 
 
This is DefaultActiveStateInterval, a member of class _ApplicationBase. 
 
This is DefaultActiveStateInterval_g2, a member of class _ApplicationBase. 
 
This is DefaultBiStable_g2, a member of class _ApplicationBase. 
 
This is DefaultBSNUrgentDelay, a member of class _ApplicationBase. 
 
TODO c 
 
Profile Config Page 2 
 
This is DefaultCalibration2_g2, a member of class _ApplicationBase. 
 
This is DefaultCalibration3_g2, a member of class _ApplicationBase. 
 
This is DefaultCalibration4_g2, a member of class _ApplicationBase. 
 
Gen 2 General Config Page 1 (Sector 24) 
 
Not used in Gen1 value doesn't matter 
 
TODO c# 1 
 
This is DefaultCrystalStartTime, a member of class _ApplicationBase. 
 
Not used in Gen2 value doesn't matter 
 
Not used in Gen1 value doesn't matter 
 
This is DefaultDMExchangeDelayMultiple_g2, a member of class _ApplicationBase. 
 
This is DefaultEventDetectionCount_g2, a member of class _ApplicationBase. 
 
This is DefaultEventDetectionPeriod_g2, a member of class _ApplicationBase. 
 
Trigger Profile Config Page 1 
 
This is DefaultHysteresis_g2, a member of class _ApplicationBase. 
 
This is DefaultLinkAcceptance, a member of class _ApplicationBase. 
 
Not used in Gen2 value doesn't matter //TODO c# -25 
 
General Config Page 3 (Sector 27) 
 
Not used in Gen2 value doesn't matter 
 
This is DefaultMaximumThreshold_g2, a member of class _ApplicationBase. 
 
Interval (Measurement) Based Sensors Profile Config Page 1 
 
Other 
 
Other 
 
This is DefaultMinimumThreshold_g2, a member of class _ApplicationBase. 
 
Not used in Gen1 value doesn't matter 
 
TODO c# 72 
 
This is DefaultRearmTime_g2, a member of class _ApplicationBase. 
 
This is DefaultReceiveSensitivity, a member of class _ApplicationBase. 
 
This is DefaultReceiveSensitivity_g2, a member of class _ApplicationBase. 
 
This is DefaultRecovery_g2, a member of class _ApplicationBase. 
 
This is DefaultReportInterval, a member of class _ApplicationBase. 
 
example of post fix 
 
General Config Page 2 (Sector 25) 
 
Not used in Gen1 value doesn't matter 
 
This is DefaultSensorHood1_g2, a member of class _ApplicationBase. 
 
Not used in Gen1 value doesn't matter 
 
This is DefaultSensorHood2_g2, a member of class _ApplicationBase. 
 
This is DefaultStandardMessageDelay_g2, a member of class _ApplicationBase. 
 
1 use aware flag normal, 0 Don't use aware flag (ForStopping the aware report) 
 
This is DefaultTimeOfDayActive_g2, a member of class _ApplicationBase. 
 
This is DefaultTransmitIntervalLink_g2, a member of class _ApplicationBase. 
 
Decomposes to 3 msgs and 30 sec interval (Bit[7:5] = the number of start-test messages 0 - 7, Bit[4:0] = Interval 0-31) 
 
This is DefaultTransmitOffset_g2, a member of class _ApplicationBase. 
 
RF Config (Sector 8) 
 
RF Config (Sector 8) 
 
This is DefaultUrgentRetries, a member of class _ApplicationBase. 
 
TODO c 
 
Name 
Description 
 
This is AmpHours, a member of class CurrentZeroToTwentyAmpBase. 
 
This is AvgCurrent, a member of class CurrentZeroToTwentyAmpBase. 
 
Data 
This is Data, a member of class CurrentZeroToTwentyAmpBase. 
 
This is DefaultBiStable, a member of class CurrentZeroToTwentyAmpBase. 
 
Profile Config Page 2 
 
This is DefaultCalibration2, a member of class CurrentZeroToTwentyAmpBase. 
 
This is DefaultCalibration3, a member of class CurrentZeroToTwentyAmpBase. 
 
This is DefaultCalibration4, a member of class CurrentZeroToTwentyAmpBase. 
 
Gen 1 General Config Page 1 (Sector 24) 
 
This is DefaultEventDetectionCount, a member of class CurrentZeroToTwentyAmpBase. 
 
This is DefaultEventDetectionPeriod, a member of class CurrentZeroToTwentyAmpBase. 
 
Trigger Profile Config Page 1 
 
This is DefaultHysteresis, a member of class CurrentZeroToTwentyAmpBase. 
 
This is DefaultMaximumNetworkHops, a member of class _ApplicationBase. 
 
This is DefaultMaximumNetworkHops_g2, a member of class _ApplicationBase. 
 
This is DefaultMaximumThreshold, a member of class CurrentZeroToTwentyAmpBase. 
 
Interval (Measurement) Based Sensors Profile Config Page 1 
 
This is DefaultMinimumThreshold, a member of class CurrentZeroToTwentyAmpBase. 
 
This is DefaultRearmTime, a member of class CurrentZeroToTwentyAmpBase. 
 
This is DefaultRecovery, a member of class CurrentZeroToTwentyAmpBase. 
 
General Config Page 2 (Sector 25) 
 
This is DefaultStandardMessageDelay, a member of class CurrentZeroToTwentyAmpBase. 
 
1 use aware flag normal, 0 Don't use aware flag (ForStopping the aware report) 
 
This is DefaultTimeOfDayActive, a member of class CurrentZeroToTwentyAmpBase. 
 
This is DefaultTransmitIntervalLink, a member of class CurrentZeroToTwentyAmpBase. 
 
Decomposes to 3 msgs and 30 sec interval (Bit[7:5] = the number of start-test messages 0 - 7, Bit[4:0] = Interval 0-31) 
 
This is DefaultTransmitOffset, a member of class CurrentZeroToTwentyAmpBase. 
 
This is implementedSensors, a member of class _ApplicationBase. 
 
This is impNums, a member of class _ApplicationBase. 
 
This is MaxCurrent, a member of class CurrentZeroToTwentyAmpBase. 
 
This is MinCurrent, a member of class CurrentZeroToTwentyAmpBase. 
 
This is ProfileType, a member of class CurrentZeroToTwentyAmpBase. 
 
Name 
Description 
 
This is CalibrateFrame, a member of class CurrentZeroToTwentyAmpBase. 
 
This is classMap, a member of class _ApplicationBase. 
 
public void setData(Listdata) { this.Data = data; 
 
This is CreateApplicationBase, a member of class _ApplicationBase. 
 
This is getAccumulate, a member of class CurrentZeroToTwentyAmpBase. 
 
This is getAveragingInterval, a member of class CurrentZeroToTwentyAmpBase. 
 
This is GetCalVal1Lower, a member of class CurrentZeroToTwentyAmpBase. 
 
This is GetCalVal1Upper, a member of class CurrentZeroToTwentyAmpBase. 
 
This is GetCalVal3FourthByte, a member of class CurrentZeroToTwentyAmpBase. 
 
This is GetCalVal3Lower, a member of class CurrentZeroToTwentyAmpBase. 
 
This is GetCalVal3ThirdByte, a member of class CurrentZeroToTwentyAmpBase. 
 
This is getCurrentShiftAware, a member of class CurrentZeroToTwentyAmpBase. 
 
This is getData, a member of class CurrentZeroToTwentyAmpBase. 
 
Returns default configurations for the sensor
@param version The version of the Sensor @param platform The Firmware Generation of your device. i.e. Commercial, Alta, Wifi @return Default configurations for the sensor 
 
This is getHysteresis, a member of class CurrentZeroToTwentyAmpBase. 
 
This is GetHystFourthByte, a member of class CurrentZeroToTwentyAmpBase. 
 
This is GetHystLower, a member of class CurrentZeroToTwentyAmpBase. 
 
This is GetHystThirdByte, a member of class CurrentZeroToTwentyAmpBase. 
 
This is getImplementedSensors, a member of class _ApplicationBase. 
 
This is getMaximumThreshold, a member of class CurrentZeroToTwentyAmpBase. 
 
This is getMinimumThreshold, a member of class CurrentZeroToTwentyAmpBase. 
 
This is getProfileType, a member of class CurrentZeroToTwentyAmpBase. 
 
This is GetType, a member of class _ApplicationBase. 
 

Allows for the update of the specific type of sensor. @param sens the Sensor object to be updated @param heartBeat How often the sensor communicates with the gateway if no activity recorded. @param awareStateHeartBeat How often the sensor communicates with the gateway while in Aware State. @param assessmentsPerHeartBeat How many times between heartbeats a sensor will check its measurements against its thresholds to determine whether it will enter the Aware State. Warning if your sensor firmware is less than 2.5.2.0 Setting assessments greater than one will cause this sensor to not self elect follow a gateway to a new channel.... more 
 
This is SetCalVal1Lower, a member of class CurrentZeroToTwentyAmpBase. 
 
This is SetCalVal1Upper, a member of class CurrentZeroToTwentyAmpBase. 
 
This is SetCalVal3FourthByte, a member of class CurrentZeroToTwentyAmpBase. 
 
This is SetCalVal3Lower, a member of class CurrentZeroToTwentyAmpBase. 
 
This is SetCalVal3ThirdByte, a member of class CurrentZeroToTwentyAmpBase. 
 
This is SetHystFourthByte, a member of class CurrentZeroToTwentyAmpBase. 
 
This is SetHystLower, a member of class CurrentZeroToTwentyAmpBase. 
 
This is SetHystThirdByte, a member of class CurrentZeroToTwentyAmpBase. 
 

sets the ReportInterval as minutes on the sensor object the next time this sensor checks in it will update @param sens the Sensor object to be updated @param heartBeat a double value this is represented in minutes so heartbeat equals 1 that is one minute @param sendSensorUpdate a Boolean flag that lets the sensor know if it should send up the new configuration 
Copyright (c) 2022. All rights reserved.
What do you think about this topic? Send feedback!