Java Mine
ContentsIndexHome
PreviousUpNext
ZeroToTwoHundredVoltBase Methods

The methods of the ZeroToTwoHundredVoltBase class are listed here.

 
Name 
Description 
 

  • Firmware must be 2.0.1 or newer
*
  • @param sensorID numeric identifier or the sensor object
  • @param observed is the last Data Message the sensor gave
  • @param actual is the actual Data Reading the sensor should be showing
  • @param currentCalibration1 is the first calibration setting set by user
// * @param isWiFi is used to identify whether this device uses WiFi
  • @return calibrated data
 
 
This is Create, a member of class ZeroToTwoHundredVoltBase. 
 
This is getData, a member of class ZeroToTwoHundredVoltBase. 
 
Returns default configurations for the sensor
@param version The version of the Sensor @param platform The Firmware Generation of your device. i.e. Commercial, Alta, Wifi @return Default configurations for the sensor 
 
This is getDelayInMilliseconds, a member of class ZeroToTwoHundredVoltBase. 
 
This is getHysteresis, a member of class ZeroToTwoHundredVoltBase. 
 
This is getMaximumThreshold, a member of class ZeroToTwoHundredVoltBase. 
 
This is getMinimumThreshold, a member of class ZeroToTwoHundredVoltBase. 
 
This is getPowerOption, a member of class ZeroToTwoHundredVoltBase. 
 
This is getProfileType, a member of class ZeroToTwoHundredVoltBase. 
 

Allows for the update of the specific type of sensor. @param sens the Sensor object to be updated @param heartBeat How often the sensor communicates with the gateway if no activity recorded. @param awareStateHeartBeat How often the sensor communicates with the gateway while in Aware State. @param assessmentsPerHeartBeat How many times between heartbeats a sensor will check its measurements against its thresholds to determine whether it will enter the Aware State. Warning if your sensor firmware is less than 2.5.2.0 Setting assessments greater than one will cause this sensor to not self elect follow a gateway to a new channel.... more 
 

Calibrates the sensor to correct values set by the user @param sens the Sensor object to be updated @param actualValue what the actual temperature of the room the sensor is located in is @param lastSensorReading the last reading the sensor took @param sendSensorUpdate a Boolean flag that lets the sensor know if it should send up the new configuration @throws Exception exception 
 

sets the ReportInterval as minutes on the sensor object the next time this sensor checks in it will update @param sens the Sensor object to be updated @param heartBeat a double value this is represented in minutes so heartbeat equals 1 that is one minute @param sendSensorUpdate a Boolean flag that lets the sensor know if it should send up the new configuration 
Copyright (c) 2022. All rights reserved.
What do you think about this topic? Send feedback!