Java Mine
|
The following tables list the members exposed by ResistiveBridgeMeterBase.
|
Name |
Description |
|
This is DefaultActiveStateInterval, a member of class _ApplicationBase. | |
|
This is DefaultActiveStateInterval_g2, a member of class _ApplicationBase. | |
|
This is DefaultBiStable, a member of class _ApplicationBase. | |
|
This is DefaultBiStable_g2, a member of class _ApplicationBase. | |
|
This is DefaultBSNUrgentDelay, a member of class _ApplicationBase. | |
|
TODO c | |
|
Profile Config Page 2 | |
|
Profile Config Page 2 | |
|
This is DefaultCalibration2, a member of class _ApplicationBase. | |
|
This is DefaultCalibration2_g2, a member of class _ApplicationBase. | |
|
This is DefaultCalibration3, a member of class _ApplicationBase. | |
|
This is DefaultCalibration3_g2, a member of class _ApplicationBase. | |
|
This is DefaultCalibration4, a member of class _ApplicationBase. | |
|
This is DefaultCalibration4_g2, a member of class _ApplicationBase. | |
|
Gen 1 General Config Page 1 (Sector 24) | |
|
Gen 2 General Config Page 1 (Sector 24) | |
|
Not used in Gen1 value doesn't matter | |
|
TODO c# 1 | |
|
This is DefaultCrystalStartTime, a member of class _ApplicationBase. | |
|
Not used in Gen2 value doesn't matter | |
|
Not used in Gen1 value doesn't matter | |
|
This is DefaultDMExchangeDelayMultiple_g2, a member of class _ApplicationBase. | |
|
This is DefaultEventDetectionCount, a member of class _ApplicationBase. | |
|
This is DefaultEventDetectionCount_g2, a member of class _ApplicationBase. | |
|
This is DefaultEventDetectionPeriod, a member of class _ApplicationBase. | |
|
This is DefaultEventDetectionPeriod_g2, a member of class _ApplicationBase. | |
|
Trigger Profile Config Page 1 | |
|
Trigger Profile Config Page 1 | |
|
This is DefaultHysteresis_g2, a member of class _ApplicationBase. | |
|
This is DefaultLinkAcceptance, a member of class _ApplicationBase. | |
|
Not used in Gen2 value doesn't matter //TODO c# -25 | |
|
General Config Page 3 (Sector 27) | |
|
Not used in Gen2 value doesn't matter | |
|
This is DefaultMaximumThreshold_g2, a member of class _ApplicationBase. | |
|
Interval (Measurement) Based Sensors Profile Config Page 1 | |
|
Interval (Measurement) Based Sensors Profile Config Page 1 | |
|
Other | |
|
Other | |
|
This is DefaultMinimumThreshold_g2, a member of class _ApplicationBase. | |
|
Not used in Gen1 value doesn't matter | |
|
TODO c# 72 | |
|
This is DefaultRearmTime, a member of class _ApplicationBase. | |
|
This is DefaultRearmTime_g2, a member of class _ApplicationBase. | |
|
This is DefaultReceiveSensitivity, a member of class _ApplicationBase. | |
|
This is DefaultReceiveSensitivity_g2, a member of class _ApplicationBase. | |
|
This is DefaultRecovery, a member of class _ApplicationBase. | |
|
This is DefaultRecovery_g2, a member of class _ApplicationBase. | |
|
This is DefaultReportInterval, a member of class _ApplicationBase. | |
|
example of post fix | |
|
General Config Page 2 (Sector 25) | |
|
General Config Page 2 (Sector 25) | |
|
Not used in Gen1 value doesn't matter | |
|
This is DefaultSensorHood1_g2, a member of class _ApplicationBase. | |
|
Not used in Gen1 value doesn't matter | |
|
This is DefaultSensorHood2_g2, a member of class _ApplicationBase. | |
|
This is DefaultStandardMessageDelay, a member of class _ApplicationBase. | |
|
This is DefaultStandardMessageDelay_g2, a member of class _ApplicationBase. | |
|
1 use aware flag normal, 0 Don't use aware flag (ForStopping the aware report) | |
|
1 use aware flag normal, 0 Don't use aware flag (ForStopping the aware report) | |
|
This is DefaultTimeOfDayActive, a member of class _ApplicationBase. | |
|
This is DefaultTimeOfDayActive_g2, a member of class _ApplicationBase. | |
|
This is DefaultTransmitIntervalLink, a member of class _ApplicationBase. | |
|
This is DefaultTransmitIntervalLink_g2, a member of class _ApplicationBase. | |
|
Decomposes to 3 msgs and 30 sec interval (Bit[7:5] = the number of start-test messages 0 - 7, Bit[4:0] = Interval 0-31) | |
|
Decomposes to 3 msgs and 30 sec interval (Bit[7:5] = the number of start-test messages 0 - 7, Bit[4:0] = Interval 0-31) | |
|
This is DefaultTransmitOffset, a member of class _ApplicationBase. | |
|
This is DefaultTransmitOffset_g2, a member of class _ApplicationBase. | |
|
RF Config (Sector 8) | |
|
RF Config (Sector 8) | |
|
This is DefaultUrgentRetries, a member of class _ApplicationBase. | |
|
TODO c |
|
Name |
Description |
|
7 = 7 = 7 | |
|
0 = 0 = 0 | |
|
30 = 30 = 30 | |
|
1 = 1 = 1 | |
|
100,000 | |
|
This is Data, a member of class ResistiveBridgeMeterBase. | |
|
0 = 0 = 0 Averaging Filter - DO NOT user ConversionFactor | |
|
1 = 1 = 1 | |
|
This is DefaultCapacity, a member of class ResistiveBridgeMeterBase. | |
|
This is DefaultCorF, a member of class ResistiveBridgeMeterBase. | |
|
0 = 0 = 0 | |
|
This is DefaultLabel, a member of class ResistiveBridgeMeterBase. | |
|
This is DefaultManualCorrection, a member of class ResistiveBridgeMeterBase. | |
|
This is DefaultManualOffset, a member of class ResistiveBridgeMeterBase. | |
|
This is DefaultMaximumNetworkHops, a member of class _ApplicationBase. | |
|
This is DefaultMaximumNetworkHops_g2, a member of class _ApplicationBase. | |
|
1e8 = 100,000,000 = +1000 | |
|
-1e8 = -100,000,000 = -1000 Noise Rejection - DO NOT user ConversionFactor | |
|
1 = 1 = 1 ADC Gain - DO NOT user ConversionFactor | |
|
0 = 0 = 0 | |
|
This is DefaultPrecision, a member of class ResistiveBridgeMeterBase. | |
|
Scale Defaults | |
|
This is DefaultScaleMax, a member of class ResistiveBridgeMeterBase. | |
|
This is DefaultScaleMin, a member of class ResistiveBridgeMeterBase. | |
|
1e5 = 100,000 = 1 | |
|
This is DefaultTypeOfBridge, a member of class ResistiveBridgeMeterBase. | |
|
1e7 = 10,000,000 = 100 | |
|
0 = 0 = 0 | |
|
This is implementedSensors, a member of class _ApplicationBase. | |
|
This is impNums, a member of class _ApplicationBase. | |
|
1e8 = 100,000,000 = +1000 | |
|
1e8 = -100,000,000 = -1000 | |
|
This is MonnitApplicationID, a member of class ResistiveBridgeMeterBase. | |
|
3 = 3 = 3 | |
|
0 = 0 = 0 | |
|
This is ProfileType, a member of class ResistiveBridgeMeterBase. | |
|
This is RatiometricPercentage, a member of class ResistiveBridgeMeterBase. | |
|
This is Temperature, a member of class ResistiveBridgeMeterBase. |
|
Name |
Description |
|
This is classMap, a member of class _ApplicationBase. | |
|
This is Create, a member of class ResistiveBridgeMeterBase. | |
|
This is CreateApplicationBase, a member of class _ApplicationBase. | |
|
This is getData, a member of class ResistiveBridgeMeterBase. | |
|
Returns default configurations for the sensor @param version The version of the Sensor @param platform The Firmware Generation of your device. i.e. GEN1, GEN2, WIFI @return Default configurations for the sensor | |
|
This is getImplementedSensors, a member of class _ApplicationBase. | |
|
This is getRatiometricPercentage, a member of class ResistiveBridgeMeterBase. | |
|
This is getTemperature, a member of class ResistiveBridgeMeterBase. | |
|
This is GetType, a member of class _ApplicationBase. | |
|
Allows for the update of the specific type of sensor. @param sens sens the Sensor object to be updated @param heartBeat How often the sensor communicates with the gateway if no activity recorded. @param awareStateHeartBeat How often the sensor communicates with the gateway while in Aware State. @param minimumThreshold Any assessments below this value will cause the sensor to enter the Aware State. @param maximumThreshold Any assessments above this value will cause the sensor to enter the Aware State. @param hysteresis A buffer to prevent the sensor from bouncing between Standard Operation and Aware State when the assessments are very... more | |
|
This is setRatiometricPercentage, a member of class ResistiveBridgeMeterBase. | |
|
This is setTemperature, a member of class ResistiveBridgeMeterBase. | |
|
sets the ReportInterval as minutes on the sensor object the next time this sensor checks in it will update @param sens sens the Sensor object to be updated @param heartBeat a double value this is represented in minutes, so if heartbeat equals 1 that is one minute @param sendSensorUpdate a Boolean flag that lets the sensor know if it should send up the new configuration |
Copyright (c) 2023. All rights reserved.
|
What do you think about this topic? Send feedback!
|