Gas_COBase.SensorEdit Method
Syntax
Java
public static void SensorEdit(Sensor sens, Double heartBeat, Double awareStateHeartBeat, Integer minimumConcentrationThreshold, Integer maximumConcentrationThreshold, Integer concentrationHysteresis, Integer minimumTimeWeightedAvgThreshold, Integer maximumTimeWeightedAvgThreshold, Integer timeWeightedAvgHysteresis, Integer failedTransmissionsBeforeLinkMode);

 

Allows for the update of the specific type of sensor. @param sens the Sensor object to be updated @param heartBeat How often the sensor communicates with the gateway if no activity recorded. @param awareStateHeartBeat How often the sensor communicates with the gateway while in Aware State. @param minimumConcentrationThreshold Any assessments below this value will cause the sensor to enter the Aware State. @param maximumConcentrationThreshold Any assessments above this value will cause the sensor to enter the Aware State. @param concentrationHysteresis A buffer to prevent the sensor from bouncing between Standard Operation and Aware State when the assessments are very close to a threshold. For example, if a Maximum threshold is set to 90 degrees and a Hysteresis of 1 degree, then once the sensor takes an assessment of 90 degrees and enters the Aware State it will remain in the Aware state until the temperature readings drop to 89 degrees similarly, at the minimum threshold the temperature will have to rise a degree above the threshold to return to Standard Operation. @param minimumTimeWeightedAvgThreshold Any assessments below this value will cause the sensor to enter the Aware State. @param maximumTimeWeightedAvgThreshold Any assessments above this value will cause the sensor to enter the Aware State. @param timeWeightedAvgHysteresis A buffer to prevent the sensor from bouncing between Standard Operation and Aware State when the assessments are very close to a threshold. For example, if a Maximum threshold is set to 90 degrees and a Hysteresis of 1 degree, then once the sensor takes an assessment of 90 degrees and enters the Aware State it will remain in the Aware state until the temperature readings drop to 89 degrees similarly, at the minimum threshold the temperature will have to rise a degree above the threshold to return to Standard Operation. @param failedTransmissionsBeforeLinkMode The number of transmissions the sensor sends without response from a gateway before it goes to battery saving link mode. In link mode the sensor will scan for a new gateway and if not found will enter battery saving sleep mode for 2 hours before trying to scan again. Lower number will allow sensors to find new gateways with fewer missed readings. Higher numbers will cause the sensor to hold it setting in a noisy RF environment better. (Zero will cause the sensor to never enter link mode. to find a new gateway channel the battery will have to be cycled out of the sensor.)

Copyright (c) 2023. All rights reserved.
What do you think about this topic? Send feedback!