C# Mine
ContentsIndexHome
ISensor Members Public Properties
Public Properties
 
Name 
Description 
 
Defines in minutes the interval at which the sensor communicates with the gateway when the sensor is in the aware state. Unless triggered to communicate earlier, the sensor will send a data message to the gateway when this many minutes elapse.  
 
Identifier of the sensor application type. (Temp/Humidity/etc)  
 
For trigger based sensors (Open/Closed, Water, etc) Determines if the sensor is bistable (triggers both directions) or monostable (triggers one direction)  
 
For interval based sensors (Temperature, Humidity, etc) Value used by profiles for calibration  
 
For interval based sensors (Temperature, Humidity, etc) Value used by profiles for calibration  
 
For interval based sensors (Temperature, Humidity, etc) Value used by profiles for calibration  
 
For interval based sensors (Temperature, Humidity, etc) Value used by profiles for calibration  
 
For Wi-Fi sensors Determines whether to use short term logging or long term data logging on the sensor when Wi-Fi connection is not available  
 
For trigger based sensors (Open/Closed, Water, etc) Sets the event count that must be breached to trigger the event  
 
For trigger based sensors (Open/Closed, Water, etc) Sets the time period in ms that the event detection count to increment before it is reset  
 
For trigger based sensors (Open/Closed, Water, etc) Determines if the sensor is normally open or normally closed, the other state triggering aware  
 
Tracks the version of firmware. Some features are only available on certain firmware versions.  
 
If set this flag will cause the General Config 2 page to be sent to the sensor Affected Fields: Recovery, RetryCount  
 
If set this flag will cause the General Config 1 page to be sent to the sensor Affected Fields: Report Interval, ActiveStateInterval, TransmitIntervalLink  
 
The value of which firmware generation the sensor belongs to ie GEN1, GEN2, WIFI  
 
For interval based sensors (Temperature, Humidity, etc) When leaving aware mode back into standard mode the sensor reading must clear the Max or Min threshold by this amount.  
 
For interval based sensors (Temperature, Humidity, etc) If reading is above this value the sensor enters aware mode  
 
For interval based sensors (Temperature, Humidity, etc) Sets often between report intervals the sensors samples against thresholds  
 
For interval based sensors (Temperature, Humidity, etc) If reading is below this value the sensor enters aware mode  
 
If set this flag will cause the action control command will be sent to the sensor  
 
If set this flag will cause the Profile Config 2 page to be sent to the sensor Affected Fields (Interval): Calibration1, Calibration2, Calibration3, Calibration4  
 
If set this flag will cause the Profile Config 1 page to be sent to the sensor Affected Fields (Interval): MeasurementsPerTransmission, MaximumThreshold, MinimumThreshold, Hysteresis Affected Fields (Trigger): EventDetectionCount, EventDetectionPeriod, EventDetectionType, BiStable, RearmTime  
 
For trigger based sensors (Open/Closed, Water, etc) sets the amount of time before a bistable trigger is reset to observe another event  
 
Defines the number of failed transmission sets before entering link mode  
 
Defines in minutes the interval at which the sensor communicates with the gateway. Unless triggered to communicate earlier, the sensor will send a data message to the gateway when this many minutes elapse.  
 
Defines the number of back to back attempts in a transmission set  
 
Unique numeric identifier of the sensor.  
 
Sets the time between link attempts in link mode. Default: 2  
Copyright (c) 2017. All rights reserved.