Name 
Description 
The action control command(s) that will be sent to the sensor  
Hold time of previous decryption failure, ensures gateway can't continually send packets with wrong encryption scheme. Only allows one reset per hour. Default: null  
If static IP is set: This is the value of the router address the gateway will send its data through to access the Internet.  
If the network connection is not available, the gateway will disable the sensor network allowing sensors to relink to a different gateway.  
Holds Initialization Vector generated in handshake. Rotates with each gateway startup Default: null  
Holds encryption key generated in handshake. Rotates with each gateway startup Default: null  
Differs by gateway type. One example is the Ethernet gateway stores it's MAC Address here  
If static IP is set: This is the value of the primary DNS server used to resolve the host address of the server. If server is defined with IP Address this value is not used.  
Tracks the version of gateway firmware. Some features are only available on certain gateway versions.  
Numeric Identifier of the gateway.  
IP address of the gateway if applicable. Default: 0.0.0.0 will inform the gateway to use DHCP to obtain an IP Address.  
If static IP is set: This is the value of the subnet mask of the network the gateway is operating on.  
Type of the gateway. Certain settings are interpreted differently for different types of gateways  
Flag that indicates if the server has urgent messages to deliver to the gateway. Responds to PollInterval for use in conjunction with Control Profile  
Record of the last message sequence received from the gateway. Used to prevent duplicate messages from being processed from a gateway.  
Defines if the gateway will trigger communication sequence when it receives an aware message. Default: true  
Defines in minutes the frequency that the gateway will request a new sensor list from the server. Default 720  
Tells the server that there are configurations that have been updated in the data store and it should push a new configuration page down to the gateway.  
If set this flag will cause the action control command will be sent to the sensor  
Defines in minutes the interval at which the gateway polls the server to check if urgent traffic exists for the gateway.  
Defines the port the server is listening for communication. Default: 3000  
Defines pre-shared key used to initiate encryption for communication to server. Must match key in gateway configuration. Default: null  
Tracks the version of radio firmware. Some features are only available on certain firmware versions.  
Defines in minutes the interval at which the gateway communicates with the server. Unless triggered to communicate earlier, the gateway will initialize a communication cycle with the server with or without data from sensors to deliver.  
If static IP is set: This is the value of the secondary DNS server used to resolve the host address of the server. If server is defined with IP Address this value is not used.  
Flag that indicates if the server should inform the gateway that the network should be reformed. Reforming the network consists of removing any sensors configured in the gateway, scanning and choosing a clear channel, and requesting the sensors to add back into the gateway.  
Address of the server. This can be either a DNS resolvable host name, or an IP Address of the server.  