The following tables list the members exposed by Sensor.
| 
 | 
 
Name   | 
 
Description   | 
![]()    | 
 
Used to fill the byte array with the proper values to send a configuration page to the sensor    | |
![]()    | 
 
used to fill sensor values with the proper values from the byte array to sent from the sensor    | |
![]()    | 
 
Builds the command used to ask the sensor to send a copy of it's configuration page    | 
| 
 | 
 
Name   | 
 
Description   | 
![]()    | 
 
This is the overview for the BatteryPercentageHelper method overload.   | |
   | 
 
Force server held configurations to be sent to the sensor at the next communication cycle.    | |
![]()    | 
 
This is LinearInterpolation, a member of class Sensor.   | |
   | 
 
This is the overview for the Sensor constructor overload.   | |
   | 
 
Defines in minutes the interval at which the sensor attempts to link/re-link with the gateway. Link heartbeats greater than 1 hour will be rounded to the nearest hour. Accepted values between 1 and 720 (1 minute to 12 hours)    | |
   | 
 
Sets number of messages sensor sends without acknowledgment from gateway before entering link mode Accepted values between 0 and 10 0 means unlimited (no self healing, power cycling senor will be required if gateway changes channel)    | |
   | 
 
Defines in minutes the interval at which the sensor communicates with the gateway. Unless triggered to communicate earlier, the sensor will send a data message to the gateway when this many minutes elapse. Accepted values between .017 and 720 (1 second to 12 hours)    | |
   | 
 
Sets number of RF packets sensor attempts to send a single message to gateway. Accepted values between 0 and 10    | 
| 
 | 
 
Name   | 
 
Description   | 
   | 
 
This is SensorPrint, a member of class Sensor.   | 
| 
 
Name   | 
 
Description   | 
| 
 
The action control command that will be sent to the sensor is urgent    | |
| 
 
The action control command(s) that will be sent to the sensor    | |
| 
 
Defines in minutes the interval at which the sensor communicates with the gateway when the sensor is in the aware state. Unless triggered to communicate earlier, the sensor will send a data message to the gateway when this many minutes elapse.    | |
| 
 
Identifier of the sensor application type. (Temp/Humidity/etc)    | |
| 
 
Identifier of the sensor application type. (Temp/Humidity/etc)    | |
| 
 
For trigger based sensors (Open/Closed, Water, etc) Determines if the sensor is bistable (triggers both directions) or monostable (triggers one direction)    | |
| 
 
For interval based sensors (Temperature, Humidity, etc) Value used by profiles for calibration    | |
| 
 
For interval based sensors (Temperature, Humidity, etc) Value used by profiles for calibration    | |
| 
 
For interval based sensors (Temperature, Humidity, etc) Value used by profiles for calibration    | |
| 
 
For interval based sensors (Temperature, Humidity, etc) Value used by profiles for calibration    | |
| 
 
For Wi-Fi sensors Determines whether to use short term logging or long term data logging on the sensor when Wi-Fi connection is not available    | |
| 
 
For trigger based sensors (Open/Closed, Water, etc) Sets the event count that must be breached to trigger the event    | |
| 
 
For trigger based sensors (Open/Closed, Water, etc) Sets the time period in ms that the event detection count to increment before it is reset    | |
| 
 
For trigger based sensors (Open/Closed, Water, etc) Determines if the sensor is normally open or normally closed, the other state triggering aware    | |
| 
 
Tracks the version of firmware. Some features are only available on certain firmware versions.    | |
| 
 
If set this flag will cause the General Config 2 page to be sent to the sensor Affected Fields: Recovery, RetryCount    | |
| 
 
If set this flag will cause the General Config 1 page to be sent to the sensor Affected Fields: Report Interval, ActiveStateInterval, TransmitIntervalLink    | |
| 
 
The value of which firmware generation the sensor belongs to ie GEN1, GEN2, WIFI, POEX    | |
| 
 
For interval based sensors (Temperature, Humidity, etc) When leaving aware mode back into standard mode the sensor reading must clear the Max or Min threshold by this amount.    | |
| 
 
For interval based sensors (Temperature, Humidity, etc) If reading is above this value the sensor enters aware mode    | |
| 
 
For interval based sensors (Temperature, Humidity, etc) Sets often between report intervals the sensors samples against thresholds    | |
| 
 
For interval based sensors (Temperature, Humidity, etc) If reading is below this value the sensor enters aware mode    | |
| 
 
Identifier of the sensor application type. (Temp/Humidity/etc)    | |
| 
 
If set this flag will cause the action control command will be sent to the sensor    | |
| 
 
If set this flag will cause the Profile Config 2 page to be sent to the sensor Affected Fields (Interval): Calibration1, Calibration2, Calibration3, Calibration4    | |
| 
 
If set this flag will cause the Profile Config 1 page to be sent to the sensor Affected Fields (Interval): MeasurementsPerTransmission, MaximumThreshold, MinimumThreshold, Hysteresis Affected Fields (Trigger): EventDetectionCount, EventDetectionPeriod, EventDetectionType, BiStable, RearmTime    | |
| 
 
For trigger based sensors (Open/Closed, Water, etc) sets the amount of time before a bistable trigger is reset to observe another event    | |
| 
 
Defines the number of failed transmission sets before entering link mode    | |
| 
 
Defines in minutes the interval at which the sensor communicates with the gateway. Unless triggered to communicate earlier, the sensor will send a data message to the gateway when this many minutes elapse.    | |
| 
 
Defines the number of back to back attempts in a transmission set    | |
| 
 
Unique numeric identifier of the sensor.    | |
| 
 
Sets the time between link attempts in link mode. Default: 2    | 
| 
 